Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Invest Ophthalmol Vis Sci ; 65(4): 14, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38578621

RESUMO

Purpose: This study aims to examine the short-term peripheral choroidal thickness (PChT) response to signed defocus blur, both with and without native peripheral aberrations. This examination will provide insights into the role of peripheral aberration in detecting signs of defocus. Methods: The peripheral retina (temporal 15°) of the right eye was exposed to a localized video stimulus in 11 young adults. An adaptive optics system induced 2D myopic or hyperopic defocus onto the stimulus, with or without correcting native peripheral ocular aberrations (adaptive optics [AO] or NoAO defocus conditions). Choroidal scans were captured using Heidelberg Spectralis OCT at baseline, exposure (10, 20, and 30 minutes), and recovery phases (4, 8, and 15 minutes). Neural network-based automated MATLAB segmentation program measured PChT changes from OCT scans, and statistical analysis evaluated the effects of different optical conditions over time. Results: During the exposure phase, NoAO myopic and hyperopic defocus conditions exhibited distinct bidirectional PChT alterations, showing average thickening (10.0 ± 5.3 µm) and thinning (-9.1 ± 5.5 µm), respectively. In contrast, induced AO defocus conditions did not demonstrate a significant change from baseline. PChT recovery to baseline occurred for all conditions. The unexposed fovea did not show any significant ChT change, indicating a localized ChT response to retinal blur. Conclusions: We discovered that the PChT response serves as a marker for detecting peripheral retinal myopic and hyperopic defocus blur, especially in the presence of peripheral aberrations. These findings highlight the significant role of peripheral oriented blur in cueing peripheral defocus sign detection.


Assuntos
Hiperopia , Miopia , Adulto Jovem , Humanos , Miopia/diagnóstico , Hiperopia/diagnóstico , Corioide , Retina , Fóvea Central , Refração Ocular
2.
Eye Contact Lens ; 50(4): 171-176, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38345090

RESUMO

OBJECTIVES: Center-distance multifocal contact lenses (MFCLs) are used to slow myopia progression. We examined the effect of two MFCLs on intraocular straylight values in myopic individuals. METHODS: Twenty-five young myopic adults were enrolled and were fit with three contact lenses (Biofinity sphere, Biofinity Multifocal, and NaturalVue Multifocal) in a random order over two study visits. Pupil size (NeurOptics VIP-300, Laguna Hills, CA) and contact lens centration were measured. Right eye intraocular straylight measurements were collected (OCULUS C-Quant; Wetzlar, Germany) and compared with a spectacle trial lens. Log straylight (LogSL) values and straylight residuals were analyzed using repeated-measures analyses of variance with Tukey-corrected post hoc t -tests. RESULTS: The mean participant age (±SD) was 24.1±1.5 years, and right eye spherical equivalent refractive error was -3.38±1.53 DS. There was no difference in mesopic pupil size between visits ( P =0.68) and no difference in contact lens centration between lenses ( P =0.99). LogSL values differed by lens type ( P =0.004). LogSL with the spectacle trial lens was significantly greater than with each contact lens type (all P <0.05), but there were no significant differences in LogSL between the three contact lenses (all P >0.05). There was no difference between the three contact lens designs for straylight residuals ( P =0.33). CONCLUSIONS: Measured intraocular straylight for both MFCLs was not different than with a spherical soft contact lens. A significant increase in intraocular straylight with spectacle trial lens correction was observed compared with all contact lenses.


Assuntos
Lentes de Contato Hidrofílicas , Miopia , Adulto , Humanos , Adulto Jovem , Acuidade Visual , Refração Ocular , Miopia/terapia , Olho
3.
Ophthalmic Physiol Opt ; 43(6): 1337-1343, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37376831

RESUMO

PURPOSE: Many presbyopic patients in both developed and developing countries use ready-made reading spectacles for their near vision correction even though the quality of these spectacles cannot always be assured. This study assessed the optical quality of ready-made reading spectacles for presbyopic correction in comparison with relevant international standards. METHODS: A total of 105 ready-made reading spectacles with powers ranging from +1.50 to +3.50 dioptres (D) in +0.50 D steps were randomly procured from open markets in Ghana and assessed for their optical quality, including induced prisms and safety markings. These assessments were done in line with the International Organization for Standardization (ISO 16034:2002 [BS EN 14139:2010]) as well as the standards used in low-resource countries. RESULTS: All lenses (100%) had significant induced horizontal prism that exceeded the tolerance levels stipulated by the ISO standards, while 30% had vertical prism greater than the specified tolerances. The highest prevalence of induced vertical prism was seen in the +2.50 and +3.50 D lenses (48% and 43%, respectively). When compared with less conservative standards, as suggested for use in low-resource countries, the prevalence of induced horizontal and vertical prism reduced to 88% and 14%, respectively. While only 15% of spectacles had a labelled centration distance, none had any safety markings per the ISO standards. CONCLUSION: The high prevalence of ready-made reading spectacles in Ghana that fail to meet optical quality standards indicates the need for more robust, rigorous and standardised protocols for assessing their optical quality before they are sold on the market. This will alleviate unwanted side effects including asthenopia associated with their use. There is also the need to intensify public health awareness on the use of ready-made reading spectacles, especially by patients with significant refractive errors and ocular pathologies.

4.
Clin Exp Optom ; : 1-7, 2023 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-37156225

RESUMO

CLINICAL RELEVANCE: The warming effect of low-level light therapy may contribute to its therapeutic mechanism which is beneficial for dry eye management. BACKGROUND: Low-level light therapy is proposed to work via cellular photobiomodulation and a potential thermal effect in dry eye management. This study examined the change in eyelid temperature and tear film stability after low-level light therapy compared to warm compress. METHODS: Participants with no to mild dry eye disease were randomised into control, warm compress, and low-level light therapy groups. The low-level light therapy group was treated with Eyelight mask (633 nm) for 15 minutes, the warm compress group with Bruder mask for 10 minutes, and the control group with an Eyelight mask having inactive LEDs for 15 minutes. Eyelid temperature was measured using the FLIR One® Pro thermal camera (Teledyne FLIR, Santa Barbara, CA, USA), and clinical measures of tear film stability were evaluated before and after treatment. RESULTS: Thirty-five participants (mean age ± SD, 27.3 ± 4.3 years) completed the study. Eyelid temperatures for external upper, external lower, internal upper and internal lower eyelids were significantly greater in the low-level light therapy and warm compress groups immediately after treatment compared to the control group (all p < 0.001). No difference in temperature was observed between the low-level light therapy and warm compress groups at all time points (all p > 0.05). Tear film lipid layer thickness was significantly greater after treatment (mean (95% CI), 13.1 nm (5.3 to 21.0), p < 0.005) but not different between groups (p > 0.05). CONCLUSION: A single treatment of low-level light therapy increased eyelid temperature immediately after treatment, but the increase was not significantly different from warm compress. This suggests that thermal effects may in part contribute to the therapeutic mechanism of low-level light therapy.

5.
Cont Lens Anterior Eye ; 46(1): 101597, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35428590

RESUMO

PURPOSE: There remains a lack of information on the perception and adoption of myopia control strategies among African eye care practitioners (ECPs). This study provides an African perspective to similar previous studies conducted in other parts of the world. METHODS: A self-administered survey in English and French was distributed to ECPs across Africa. The items on the questionnaire assessed their level of concern about the increasing prevalence of paediatric myopia, perceived efficacy, opinions on, and adoption of various myopia management modalities. RESULTS: Responses were obtained from 330 ECPs working in 23 African countries. Respondents were highly concerned about the increasing prevalence of paediatric myopia in their clinic (median 8/10) and perceived approved myopia control soft contact lenses as the most effective at slowing myopia progression (mean perceived reduction in myopia progression ± SD; 53.9 ± 27.1%), followed by single vision spectacles (53.1 ± 30.9%), and orthokeratology (52.8 ± 28.0%). Multifocal soft contact lenses (40.4 ± 25.8%) and pharmaceutical agents such as topical atropine drops (39.5 ± 27.1%) were perceived as least effective in slowing myopia progression. Although ECPs reported being aware of various myopia control strategies, they still mainly prescribed single vision spectacles to a large proportion (64.3 ± 29.9%) of young progressing myopes. Nearly one-third (27%) of ECPs who prescribed single vision lenses stated they were concerned about the cost implications to patients. Other reported concerns included safety of, and inadequate information about myopia control options. CONCLUSIONS: African ECPs continue to prescribe single vision lenses for progressing myopes despite being aware of the various myopia control options. Practitioners' perceptions of the efficacy of several modalities to slow myopia progression do not align with the current best evidence. Clear practice guidelines and continuing education on myopia control are warranted to inform and guide the management of myopic patients in Africa.


Assuntos
Lentes de Contato Hidrofílicas , Miopia , Humanos , Criança , Miopia/epidemiologia , Miopia/terapia , Atropina/uso terapêutico , Inquéritos e Questionários , África/epidemiologia , Progressão da Doença
6.
Optom Vis Sci ; 99(4): 342-349, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35121719

RESUMO

SIGNIFICANCE: The contrast sensitivity (CS) function provides a more detailed assessment of vision than visual acuity. It was found that center-distance multifocal contact lens designs that are increasingly being prescribed for myopia control reduce distance photopic and mesopic CS in nonpresbyopic patients across a range of spatial frequencies. PURPOSE: This study aimed to determine the effect of center-distance multifocal soft contact lenses (MFCLs) on CS under photopic and mesopic conditions in nonpresbyopic patients. METHODS: Twenty-five myopic, nonpresbyopic adults were fitted binocularly with three lenses: Biofinity single vision contact lens (SVCL), Biofinity Multifocal D +2.50 add, and NaturalVue Multifocal in random order. Contrast sensitivity was measured at distance (4 m) under photopic and mesopic conditions and at near under photopic conditions. Log CS by spatial frequency and area under the log contrast sensitivity function (AULCSF) were analyzed between lenses. RESULTS: Distance photopic CS at each spatial frequency was higher with the SVCL than the MFCLs (P < .001), but there was no difference between the MFCLs (P = .71). Distance mesopic CS from 1.5 to 12 cycles per degree (cpd) was higher with the SVCL than the MFCLs (all P < .02); however, at 18 cpd, there was no difference in CS between NaturalVue and the SVCL (P = .76), possibly because of spurious resolution. Photopic AULCSF for the SVCL was roughly 10% greater than both MFCLs. Contrast sensitivity at near was generally similar between lenses, only slightly lower with the NaturalVue at 11 and 15.5 cpd, but AULCSF at near was not different between lenses (P > .05). CONCLUSIONS: Multifocal contact lenses reduce distance contrast sensitivity under both photopic and mesopic conditions. There is no clinically significant difference in near CS among all three lenses. These data show that MFCLs have effects on vision that are not captured by standard high-contrast visual acuity testing.


Assuntos
Lentes de Contato Hidrofílicas , Miopia , Adulto , Sensibilidades de Contraste , Humanos , Miopia/terapia , Testes Visuais , Acuidade Visual
7.
Optom Vis Sci ; 98(8): 997-998, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34393207
8.
Optom Vis Sci ; 98(3): 272-279, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33771957

RESUMO

PURPOSE: The purpose of this study was to examine the visual performance of center-distance MFCLs in nonpresbyopic adults under different illumination and contrast conditions compared with a single-vision contact lens (SVCL). METHODS: Twenty-five adult subjects were fit with three different lenses (CooperVision Biofinity D MFCL +2.50 add, Visioneering Technologies NaturalVue MFCL, CooperVision Biofinity sphere). Acuity and reading performance were evaluated. RESULTS: A statistically significant difference in high-contrast distance acuity was observed (Biofinity, -0.18 ± 0.06; Biofinity MFCL, -0.14 ± 0.08; NaturalVue MFCL, -0.15 ± 0.03; repeated-measures [RM] ANOVA, P = .02). Under mesopic, high-contrast conditions, MFCLs performed worse than SVCLs (Biofinity, -0.05 ± 0.091; Biofinity MFCL, +0.03 ± 0.09; NaturalVue MFCL, +0.05 ± 0.091; RM-ANOVA, P < .0001). Under low-contrast conditions, MFCLs performed one line worse in photopic lighting and two lines worse under mesopic conditions (RM-ANOVA, P < .0001). Glare reduced acuity by 0.5 logMAR for all lenses (RM-ANOVA, P < .001). A statistically significant difference in near acuity was observed (RM-ANOVA, P = .02), but all lenses achieved acuity better than -0.1 logMAR (Biofinity, -0.16 ± 0.06; Biofinity MFCL, -0.17 ± 0.04; NaturalVue MFCL, -0.13 ± 0.08). Reading performance in words per minute (wpm) was worse with MFCLs (Biofinity MFCL, 144 ± 22 wpm; NaturalVue MFCL, 150 ± 28 wpm) than with SVCLs (156 ± 23 wpm; RM-ANOVA, P = .02) regardless of letter size (RM-ANOVA, P = .13). No difference in acuity between the MFCLs was detected (RM-ANOVA: all, P > .05). CONCLUSIONS: Multifocal contact lenses perform similarly to SVCLs for high-contrast targets and display reduced low-contrast acuity and reading speed. Practitioners should recognize that high-contrast acuity alone does not describe MFCL visual performance.


Assuntos
Lentes de Contato , Miopia/terapia , Acuidade Visual/fisiologia , Adulto , Visão de Cores/fisiologia , Sensibilidades de Contraste/fisiologia , Estudos Cross-Over , Feminino , Ofuscação , Humanos , Luz , Masculino , Miopia/fisiopatologia , Ajuste de Prótese , Refração Ocular/fisiologia , Método Simples-Cego , Adulto Jovem
9.
Ophthalmic Physiol Opt ; 41(2): 393-400, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33295033

RESUMO

PURPOSE: Centre-distance multifocal contact lenses (MFCLs) for myopia control are thought to slow myopia progression by providing both clear foveal vision and myopic defocus. Characterising the power profile of lenses is important to understanding their possible effects on retinal defocus when worn. The power profiles of three commercially available MFCLs were determined. METHODS: Three centre-distance MFCL designs were studied: Biofinity Multifocal D +2.50 add (comfilcon A), Proclear Multifocal D +2.50 add (omafilcon A), and NaturalVue Multifocal (etafilcon A). Two lenses each in power from -1.00D to -6.00D in 1D steps were stored in ISO 18369-3:2017 standard phosphate buffered saline for 24 h. Optical power profiles were measured in a wet cell with the SHSOphthalmic profiler accounting for centre thickness and manufacturer-reported material refractive index. Sagittal power maps from the SHSOphthalmic were exported, and custom MATLAB code was used to generate power profiles by averaging along the vertical and horizontal meridians. One-way anova with Tukey's HSD post-hoc t-tests were used to analyse maximum add power by lens design. RESULTS: Plus power increased out from the lens centre for all three MFCLs. Power profiles of Biofinity D and Proclear D MFCLs show three distinct areas within the optic zone; the distance zone (from lens centre to about 1.6 mm radius), intermediate zone (about 1.6 mm radius to 2.1 mm) and near zone (about 2 mm radius to 4 mm). For NaturalVue MFCLs, plus power starts increasing almost immediately from the lens centre, reaching maximum measured mean plus power at a radius of 2.7 mm. From 2.7 mm to 3.0 mm, there was a decrease in plus power, which was then generally maintained out to the optic zone edge. Across all lens powers, maximum add power was highest with the NaturalVue MFCL (+3.32 ± 0.44D), then Proclear D (+1.84 ± 0.28D) and Biofinity D (+1.47 ± 0.34D) MFCLs (all p < 0.04). Add power peaked at different locations for different lens powers and designs. CONCLUSIONS: Power profiles of MFCLs vary based on lens design and power. These power profiles are consistent with reported myopic and hyperopic changes in peripheral refraction with MFCLs and provide some explanation for reported differences in peripheral refraction with these MFCLs. Further work is needed to determine whether these power profile differences influence myopia progression.


Assuntos
Acomodação Ocular/fisiologia , Lentes de Contato Hidrofílicas/normas , Hiperopia/terapia , Miopia/terapia , Refração Ocular/fisiologia , Acuidade Visual , Desenho de Equipamento , Humanos , Hiperopia/fisiopatologia , Miopia/fisiopatologia , Refratometria/métodos , Testes Visuais
10.
Clin Exp Optom ; 103(1): 44-54, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31378996

RESUMO

Orthokeratology has undergone drastic changes since first described in the early 1960s. The original orthokeratology procedure involved a series of lenses to flatten the central cornea and was plagued by variable results. The introduction of highly oxygen-permeable lens materials that can be worn overnight, corneal topography, and reverse-geometry lens designs revolutionised this procedure. Modern overnight orthokeratology causes rapid, reliable, and reversible reductions in refractive error. With modern designs, patients can wear lenses overnight, remove them in the morning, and see clearly throughout the day without the need for daytime refractive correction. Modern reverse-geometry lens designs cause central corneal flattening and mid-peripheral corneal steepening that provides clear foveal vision while simultaneously causing a myopic shift in peripheral retinal defocus. The peripheral myopic retinal defocus caused by orthokeratology is hypothesised to be responsible for reductions in myopia progression in children fitted with these lenses. This paper reviews the changes in orthokeratology lens design that led to the reverse-geometry orthokeratology lenses that are used today and the optical changes these lenses produce. The optical changes reviewed include changes in refractive error and their time course, high- and low-contrast visual acuity changes, changes in higher-order aberrations and visual quality metrics, changes in accommodation, and changes in peripheral defocus caused by orthokeratology. The use of orthokeratology for myopia control in children is also reviewed, as are hypothesised connections between orthokeratology-induced myopic peripheral defocus and slowed myopia progression in children, and safety and complications associated with lens wear. A better understanding of the ocular and optical changes that occur with orthokeratology will be beneficial to both clinicians and patients in making informed decisions regarding the utilisation of orthokeratology. Future research directions with this lens modality are also discussed.


Assuntos
Lentes de Contato , Miopia/terapia , Óptica e Fotônica , Procedimentos Ortoceratológicos , Aberrações de Frente de Onda da Córnea/prevenção & controle , Humanos , Miopia/fisiopatologia , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...